The SS-3100 system for fMRI adds special features to the Silent Scan SS-3000 system.

  • Choose between clinical and functional settings so you can precisely set audio levels from your stimulation source.
  • A X10 gain mode gives you the flexibility to use laptops as audio stimulation sources.
  • A 1Khz test tone mode is a convenient way to set reference levels.

The SS-3100 is calibrated, so you have a measure of sound pressure level (SPL) as a function of input frequency and level. The SS-3100 is also supplied with a dual channel, one-third octave (OTO) filter bank that has been set so the SS-3100 has a flat frequency response; you can also adjust the filter to your own specifications.

The excellent noise reduction offered by the Silent Scan headset, as well as a high SPL output, ensures audio stimulation for the most demanding applications.

And Silent Scan’s great reliability means you spend time on your research, not time worrying about your equipment.


 
Avotec Audio Solution

Visual systems are the perfect
complement to the Silent Scan system.

read more
Avotec Audio Solution

Add fMRI tools to Silent Scan to
increase your capabilities.

read more
   
  • Overview
  • Technical Specifications

The SS-3100 system adds three fMRI specific features to the SS-3000 system; mode selection, third octave (OTO) filter bank, and audio calibration.

Four functional modes can be selected: clinical, functional, X10 gain, and test. In the clinical mode, the sound level output can be changed with the console volume control. In the functional mode, there is a fixed sound pressure level gain setting for the system, so the sound level output is effectively controlled by varying the input signal level; this allows for precise and repeatable sound pressure level settings .In the x10 input mode, a gain of 10 is applied to the input signal level; this feature is supplied to assist with the sometimes anemic outputs of computer sound cards. The test mode outputs a fixed gain, 1 Khz test tone that can be used for setting reference levels.

The third octave (OTO) filter bank is factory adjusted to give a flat frequency response (+/- 4dB) across the operating range . This makes the design of your audio stimulation that much simpler. Additionally, the SS-3100 system is calibrated so you know what the SPL is as a function of input frequency and amplitude.

 

Components: communication console with gooseneck microphone; AC power supply with power cord; transducer with mounting bracket; full coverage and stethoscopic headsets; sample packs of disposable headset covers and eartips; DC power/signal cabling between console and transducer; RF filter for penetration panel connection; headset bracket; Scan-Lock™ Plus research tubing assembly; patient alarm bulb; alarm bulb bracket; one-third octave (OTO), two-channel filter bank; acoustic calibration.

Physical: console, 7”Hx5”Wx 8”D, 3 lbs; AC power supply, x x x x x , xx lbs; transducer housing, 4”Hx6”Wx3”D, 13 oz.; DC power cable (console cable plus magnet cable) per site specification, 200 feet (max); RF filter, 15-pin sub-D opening in pen panel required; stethoscopic headset 0.7 oz.; full coverage headset 13 oz.; tubing assembly, 19 oz.

Electrical (site specific): AC transformer 110VAC (50-60Hz) /220VAC (50Hz); fused FST 1A (115VAC) / FST 0.5A (220VAC). OTO filter bank 115VAC (60Hz), requires adaptor for other line voltages.

Audio (output): Frequency response (typical): Flat response (+/-) 4dB 200-4500Hz; calibration points at 200, 500, 1000, 2000, 3000, 4000 Hz; time delay 9ms (nominal); non-dispersive acoustic propagation (constant phase delay).

Certifications: ETL , CE

Cabling: DC power/signal cables (4-shielded twisted pairs) in two sections (console to pen panel, and pen panel to transducer); IEC power cord, plug type site specific, 3-wire grounded, 6 feet nominal.

Colors: housings, headsets and connectors: white.

Warranty: one year warranty; optional three year extension.

Specifications subject to change without notice.

 